Part Number Hot Search : 
X24C08PM FAN7040 SF2178A MAX3006E 12003 ON0373 2SB1275 T1010
Product Description
Full Text Search
 

To Download FSP400-60THA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Sparkle Power Inc.
A Leading Power Supply manufacturer
Web site: www.sparklepower.com
FSP400-60THA
400 Watts ATX12V 2.0 Switching Power Supply Features
* * * * * * *
Specification
*
Complied with ATX12V 2.0 standard High efficiency and reliability Remote On/Off function Internal 12V DC fan included Noise Killer (Thermal fan speed control function) Low noise and ripple Complies with FCC part 15 subpart J Class B and CISPR 22 Class B
Operating Temperature Range: 0C ~ 50C, 25C On 400W, 50C On 350W, De-rate 2W/C.
* * *
Storage & Shipping Temperature Range:-20C~65C Humidity: 90% on operating and 95% on storage Dielectric Withstand: Input to frame ground 1800V AC for 1 second
* * * *
Efficiency: 70% Min at 115/230AC On Full load Rise Time: Less than 20ms on all output Hold-up Time: 17ms minimum at nominal input voltage Power Good Signal: Power on delay time 100 ms to 500 ms, off delay 1ms minimum (TTL and CMOS compatible)
* * * *
Output over voltage, short circuit, and over current protection 100% Hi-pot, ATE, and burn-in tested Re-settable power shut down Approved by UL 60950, CSA C22.2 Level 3, TUV EN60950, NEMKO (CB Report)
* * *
Leakage Current: Not exceed 3.5mA MTBF: 100,000 hours on maximum load at +25 C degree Dimension (WxHxL): 150x86x140mm/6"x3.4"x5.5" inches
Input Characteristics
Input Range: 10% of 115/230V AC, Manual selection Frequency: 47~63Hz Input Current 10A/115Vac(rms), 5A/230Vac(rms) Inrush Current: 90A max cold start, 120A warm measured at 264rms/50Hz
Output Characteristics
Output Voltage +3.3V +5V +12V1 +12V2 -12V +5Vsb Min Load 0.5A 1.0A 1.0A 1.0A 0.0A 0.0A Normal Load 15A 14A 7A 8.5A 0.4A 1A Max Load 30A 28A 14.0A 15.0A 0.5A 2.0 A Load Reg. 5% 5% 5% 5% 10% 5% Line Reg. 1% 1% 1% 1% 2% 1% Ripple & Noise 50mV P-P 50mV P-P 120mV P-P 120mV P-P 120mV P-P 50mV P-P
*+5V and +3.3V total output not exceed 150W *When +3.3V is load on 30A, the +5V maximum load is 10.0A *When +3.3V is load on 3.0A, the +5V maximum load is 28A *+3.3V, +5V, +12V1, and +12V2 total output not exceed 385W
Sparkle Power Inc. Main Office 1000 Rock Avenue San Jose, CA 95131 TEL: 408-519-8888 FAX: 408-519-9999 E-MAIL: info@sparklepower.com
Sparkle Power Inc. Los Angeles Office 17071 Green Drive City of Industry, CA 91745 TEL: 626-839-7180 FAX: 626-839-3395
Sparkle Power Inc. Colorado Office 1316 Indian Paintbrush Lane Longmont, CO 80503 TEL: 303-776-3281 FAX: 303-776-7645


▲Up To Search▲   

 
Price & Availability of FSP400-60THA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X